Dependence of inter-electrode gap separation on the Positive and Negative Pin-Grid Plasma Corona Discharge

Authors

  • Pirzheen O. Abdullah University of Duhok
  • Sabah I. Wais University of Duhok

Keywords:

Corona Discharge, Corona inception Voltage, Point-grid electrode system

Abstract

In this work, both positive and negative corona discharge of pin-grid geometrical configuration was studied and the necessary modification of the general law of corona discharge was proposed. The current-voltage measurements were performed at room temperature and at different inter electrode separations. The variation of dimensional constant K and corona inception voltage Vo with pin-grid separations S were subjected into the general law of corona discharge using the least square fitting method in Log-Log scale. The relationship between corona current and different voltage (V-Vo) was investigated to find the acceptable value of exponent n. The least square fitting for all variations of corona parameters was based on the highest R-square value of obtained straight lines for individual measurements. It was found that value of exponent n for both polarities is larger compared to the empirical formula proposed previously for the general law of corona discharge.

Published

2020-06-24

How to Cite

O. Abdullah, P., & I. Wais, S. (2020). Dependence of inter-electrode gap separation on the Positive and Negative Pin-Grid Plasma Corona Discharge. Academic Journal of Nawroz University (AJNU), 9(3). Retrieved from https://journals.nawroz.edu.krd/files/article/view/939

Issue

Section

Articles