Compressive Sensing Based Brain MRI Medical Image Compression and Encryption Using Three Different Basis Transformers

Authors

  • Hozan Kareem Saber Department of Electrical and Computer Engineering, College of Engineering, University of Duhok, Kurdistan Region-Iraq
  • Mohammed Ahmed Shakir Department of Electrical and Computer Engineering, College of Engineering, University of Duhok, Kurdistan Region-Iraq

DOI:

https://doi.org/10.25007/ajnu.v13n2a1570

Abstract

Basis transformers and measurement matrices have an effective role in compressing and encrypting images. Therefore, choosing a suitable basis transformer for use in image sparsening with Compressive Sensing (CS) system is very important for image compression and encryption. There are different types of basis transformers such as discrete cosine transform (DCT), fast Fourier transform (FFT) and discrete wavelet transform (DWT). In this research, a CS algorithm is proposed with three different transformers for compression and encryption of brain MRI medical images. The three transformers DCT, FFT and DWT with daubechies1 (db1) filter are used for MRI image sparsity. CS with DWT is applied to three detail sub images that show the vertical, horizontal, and diagonal detail in the image. A random partial Fourier measurement matrix was used to generate the measurement matrix for image sparsity compression and encryption. The algorithm L1 norm was used to reconstruct the compressed and encrypted image. The main objective of this study is to compare the use of the three transformers with CS (CS with DCT, CS with FFT, and CS with DWT), thus choosing the appropriate transform with CS for compression and encryption of the brain MRI medical images. In this paper, eight different sensing matrices were also studied and the most suitable one with the sparse image was selected. The most appropriate choice was the random partial Fourier measurement matrix. The performance of the proposed system was evaluated using elapsed time, compression ratio (CR), compression factor (CF), space savings, power to signal ratio (PSNR), structural similarity index (SSIM), mean square error (MSE). Experimental results showed that the technique of CS with DWT outperformed the technique of CS with DCT and FFT. Compression technology of CS with DWT achieved the highest CR of 3.7786 with PSNR of 39.1039 dB, SSIM=0.9944, MSE=1.0984, the space savings=73.54 %, CF=0.2646 and elapsed time=24.312920 second.

Downloads

Download data is not yet available.

References

H. K. Saber and M. A. Shakir, "A Review on Medical Image Compression and Encryption Using Compressive Sensing," in 2022 International Conference on Computer Science and Software Engineering (CSASE), 2022, pp. 312-318: IEEE.

M. T. Kumar and M. B. Reddy, "Compressive Sensing Based Simultaneous Data Compression and Convergent Encryption for Secure Deduplication," International Journal of Computer Science and Information Security (IJCSIS), vol. 15, no. 9, 2017.

L. Wang, L. Li, J. Li, J. Li, B. B. Gupta, and X. Liu, "Compressive sensing of medical images with confidentially homomorphic aggregations," IEEE Internet of Things Journal, vol. 6, no. 2, pp. 1402-1409, 2018.

S.-H. Hsieh, T.-H. Hung, C.-S. Lu, Y.-C. Chen, and S.-C. Pei, "A secure compressive sensing-based data gathering system via cloud assistance," IEEE Access, vol. 6, pp. 31840-31853, 2018.

S. M. R. Islam, X. Huang, and K. L. Ou, "Image compression based on compressive sensing using wavelet lifting scheme," The International Journal of Multimedia & Its Applications, vol. 7, no. 1, p. 1, 2015.

R. Kher and Y. Patel, "Medical image compression framework based on compressive sensing, DCT, and DWT," Biology, Engineering, and Medicine, vol. 2, no. 2, pp. 1-4, 2017.

R. M. Thanki and A. Kothari, "CS Theory-Based Compression Techniques for Medical Images," in Hybrid and Advanced Compression Techniques for Medical Images: Springer, 2019, pp. 63-82.

K. Suresh, "Reconstruction of MRI images based on compressive sensing," in 2019 International Conference on Communication and Signal Processing (ICCSP), 2019, pp. 0787-0791: IEEE.

I. D. Irawati, S. Hadiyoso, and Y. S. Hariyani, "Multi-wavelet level comparison on compressive sensing for MRI image reconstruction," Bulletin of Electrical Engineering and Informatics, vol. 9, no. 4, pp. 1461-1467, 2020.

Z. Hua, K. Zhang, Y. Li, and Y. Zhou, "Visually secure image encryption using adaptive-thresholding sparsification and parallel compressive sensing," Signal Processing, vol. 183, p. 107998, 2021.

K. Srinivas, N. Srinivas, P. K. Kumar, and G. Pradhan, "Performance comparison of measurement matrices in compressive sensing," in International Conference on Advances in Computing and Data Sciences, 2018, pp. 342-351: Springer.

M. A. SHAKIR, "Compressive Sensing Based Signal Recovery With Different Transforms," Journal of Duhok University, pp. 129-141, 2017.

A. Kurniawan, T. W. Purboyo, and A. L. Prasasti, "Implementation of image compression using discrete cosine transform (dct) and discrete wavelet transform (dwt)," International Journal of Applied Engineering Research, vol. 12, no. 23, pp. 13951-13958, 2017.

E. Candes and J. Romberg, "l1-magic: Recovery of sparse signals via convex programming," URL: www. acm. caltech. edu/l1magic/downloads/l1magic. pdf, vol. 4, no. 14, p. 16, 2005.

V. Upadhyaya and M. Salim, "To Analyse the Effect of Relaxation Type on Magnetic Resonance Image Compression Using Compressive Sensing," International Journal of Online & Biomedical Engineering, vol. 17, no. 4, 2021.

R. Monika, S. Dhanalakshmi, R. Kumar, R. Narayanamoorthi, and K. W. Lai, "An efficient adaptive compressive sensing technique for underwater image compression in IoUT," Wireless Networks, pp. 1-15, 2022.

Z. Wang, A. C. Bovik, H. R. Sheikh, and E. P. Simoncelli, "Image quality assessment: from error visibility to structural similarity," IEEE transactions on image processing, vol. 13, no. 4, pp. 600-612, 2004.

https://www.kaggle.com/datasets/masoudnickparvar/brain-tumor-mri-dataset.

Published

2024-06-30

How to Cite

Kareem Saber, H. ., & Ahmed Shakir, M. (2024). Compressive Sensing Based Brain MRI Medical Image Compression and Encryption Using Three Different Basis Transformers. Academic Journal of Nawroz University, 13(2), 696–714. https://doi.org/10.25007/ajnu.v13n2a1570

Issue

Section

Articles